Automatic Potentiometric (pH/mV/ISE) Titration System - HI902C

Overview Group

Overview

Automatic Potentiometric (pH/mV/ISE) Titration System - HI902C

A Better Titration Experience

Our friendly technical consultants take pride in helping make your titrator selection easy – every step of the way. From determining materials and methods to installation and beyond.

Learn More >

Request Consultation

The HI902C is an automatic titrator that complements our wide range of products dedicated to efficient and accurate laboratory analysis. The HI902C potentiometric titrator can perform acid/base, redox (ORP), complexometric, precipitation, non-aqueous, argentometric, and ion selective titrations, as well as back titrations and titre determinations. This powerful titrator automatically dispenses the titrant, detects the endpoint, and performs all necessary calculations and graphing. In addition to titration, the HI902C also operates as a fully functional pH, mV/ORP, and ion selective electrode (ISE) meter.

 

View All Hanna Instruments Titrators

 

Titrator Capabilities

HI902C Angled

Enhanced Security Options

Administrative users can set a PIN code on the device protecting against unauthorized access. Titration method options and results are tamper-proof while a non-administrator operates the titrator, ensuring records remain safe, secure, and traceable.

Dynamic Titrant Dosing

The dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.

Signal Stability Timing

The signal stability feature monitors when the mV response of the titration reaction stabilizes before providing the next titrant dose. This ensures reliable measurement values throughout the length of a titration.

Equivalence Endpoint Detection

Equivalence endpoint detection is critical in applications where fixed endpoints are not specified in standard methods. This endpoint indicates where the mV response from the titration is greatest with respect to the volume of titrant dosed.

Multiple Equivalence Point Detection

The HI902C can detect multiple equivalence points during one titration as specified and required in certain standard methods and applications.

Method Sequencing

The HI902C offers users the option of linking two methods. This allows for two analyses to be run on the same sample including direct measurements, single endpoint titrations, multiple equivalence point titrations, and back titrations.

Multiple Titration Types

Paired with the right electrode from our sensor line, our potentiometric titrator can perform acid/base, redox (ORP), complexometric, precipitation, non-aqueous, argentometric, and ion selective titrations, as well as back titrations and titre determinations.

Direct Measurement Functionality

The HI902C performs as a high accuracy pH, ORP, and ion selective meter that can link, log, and report direct measurements. Users can easily track and manage data without the hassle of manual record keeping.

 

Burettes & Dosing System

 

Exchangeable Burette System

With Hanna’s Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents preventing cross-contamination and saving time.

Multiple Burette Sizes

The HI902C comes standard with a 25 mL burette but may be equipped with a 5 mL, 10 mL, or 50 mL burette. Each burette is constructed with a ground glass syringe and chemically resistant PTFE plunger.

Precision Dosing Pump

Our unmatched 40,000 step piston driven pump is capable of dosing extremely small and highly accurate volumes of titrant or reagent.

Chemically Resistant Tubing

Aspiration and dispensing tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light sensitive reagents.

Automatic Reagent Addition

A second burette may be programmed to volumetrically dispense reagent prior to titration or direct measurement. This helps achieve consistent and accurate results and prevents operator errors such as incorrect volumes or forgetting reagent addition.

Burettes and Dosing

Interface & Display

Screenshots

Interactive Color Display

A large, color LCD screen clearly shows the chosen titration method along with results, units, titration volume, temperature, and mV or pH values.

Detailed Titration Graphs

A real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.

Simple & Quick Navigation

Virtual key selections present on the display allow for simple and quick navigation between screens and menus without getting lost in a nest of information.

 

Data & Storage

 

Customizable Analysis Reports

Each analysis report is fully customizable so users can ensure they are storing and filing the appropriate data required for their application.

Flexible GLP Management

All necessary GLP (Good Laboratory Practice) information can be recorded with each sample including: sample identification, company and operator name, date, time, electrode ID codes, and calibration information.

Effortless Data Transfer

Data can easily be transferred to a USB flash drive or PC with the Hanna HI900PC application software. The conveniently located port allows for the transfer of titration methods, titration reports, and software upgrades via USB flash drive.

USB Storage

 

Connectivity & Functionality

HI902C Angled

Autosampler Connectivity

The HI902C works seamlessly with our HI921 Autosampler featuring 16 or 18 sample tray options, automatic tray identification, and automatic beaker detection. Up to three peristaltic pumps for reagent addition and removal can be connected and real-time analysis and sequencing progress is visible on the HI902C display as well as indicated by the LED lights of the Autosampler.

Multifunctional

HI902C functions as a titrator, pH meter, mV/ORP meter, and ISE meter. Valuable laboratory bench space is saved, and multiple analyses can be performed on one sample.

Multiple Connections

The titrator offers device support for two analog boards, allowing up to two electrodes, two burettes, and two stirrers to be connected to one unit simultaneously.

Multiple Peripherals

Users can print reports directly from the titrator using a parallel port interface. An external monitor and keyboard may be attached for added versatility, as well as an analytical balance for automatic sample mass entry for titrations.

 

Methods of Analysis

 

Customizable Methods

The HI902C can store up to 100 user-defined or standard titration and direct measurement methods. Each method may be modified and optimized for performance based on application and user requirements.

Titration Method Support

Onsite installation, training, and customization is available from one of our Applications or Service experts. Hanna offers continued support for any questions you might have along the way.

Market Specific Methods Packs

Hanna offers titration method packages for various markets including food, beverage, dairy, wine, and more. Ask our Sales Consultants about our library of market specific titration methods.

Adaptable Standard Methods

Our technical experts can program and optimize standard methods developed by such affiliations as ISO, ASTM, AOAC, AOCS, EPA, and more directly onto your titrator. Ask our Sales Consultants which standard methods are possible with our HI902C system.

 

Request a Consultation

Electrodes

pH Specifications

pH Range
-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH

pH Resolution
0.1; 0.01; 0.001 pH

pH Accuracy (@25ºC/77ºF)
±0.001 pH

pH Calibration
up to five-point calibration, eight standard buffers and five custom buffers

mV Specifications

mV Range
-2000.0 to 2000.0 mV

mV Resolution
0.1 mV

mV Accuracy (@25ºC/77ºF)
±0.1 mV

mV Calibration
single-point offset

ISE Specifications

ISE Range
1•10⁻⁶ to 9.99•10¹⁰

ISE Resolution
1; 0.1; 0.01

ISE Accuracy
±0.5% monovalent; ±1% divalent

ISE Calibration
up to five-point calibration, seven standard solutions and five user-defined standards

Temperature Specifications

Temperature Range
-5.0 to 105.0°C; 23.0 to 221.0°F; 268.2 to 378.2K

Temperature Resolution
0.1°C; 0.1°F; 0.1K

Temperature Accuracy (@25ºC/77ºF)
±0.1°C; ±0.2°F; ±0.1K, excluding probe error

Temperature Compensation
manual (MTC) or automatic (ATC)

Additional Specifications

Programmable Stirrer
propeller type, 100 to 2500 rpm, resolution 100 rpm

Display
5.7” (320 x 240 pixel) backlit color LCD

Burette Sizes
5, 10, 25, and 50 mL

Burette Resolution
1/40000

Display Resolution
0.001 mL

Dosing Accuracy
±0.1% of full burette volume

Methods
up to 100 methods (standard and user-defined)

Burette Auto-Detection
burette size is automatically recognized when inserted into the unit

Flow Rate
user-selectable from 0.1 mL/min to 2 x burette volume/min

Endpoint Determination
equivalence point (1st or 2nd derivative) or fixed pH/mV value

Potentiometric Titrations
acid/base (pH or mV-mode), redox, precipitation, complexometric, non-aqueous, ion-selective, argentometric

Measurement Units
user-specified expression of concentration units to suit specific calculation requirements

Real-Time & Stored Graphs
mV-volume or pH-volume titration curve, 1st derivative curve or 2nd derivative curve; pH mode, mV mode or ISE mode: pH/mV/concentration versus time

USB Host (Side)
flash drive compatibility for transfer of methods and reports

Peripherals (Rear)
connections for VGA display, PC-keyboard, parallel printer, USB device input, RS232, interface for autosampler

GLP Conformity
instrumentation data storage and printing capabilities

Languages
English, Portuguese, Spanish

Operating Environment
10 to 40°C (50 to 104°F), up to 95% RH

Storage Environment
-20 to 70°C (-4 to 158°F), up to 95% RH

Power Supply
100-240 VAC; "-01" models, US plug (type A); "-02" models, European plug (type C)

Dimensions
390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in)

Weight
approximately 9 kg (20 lbs.) (with one pump, stirrer and sensors)

Video

Please wait while the page is loading